| Dust
Detect 1000
The Dust Detect 1000 is a single device dust detector
that has been specifically designed to continuously
monitor the flow of particulate emissions from small
stacks and emission points being passed through an air
filtration system. It easily installs in the exhaust
ductwork and can be used with several types of filtration
systems. The probe on the Dust Detect 1000 is able to
recognize abnormal particulate levels outside user-defined
preset parameters and initiates an alarm when changes
in emission exceed these levels.
Features
-----------------
- Continuous monitoring of emissions through an air
filtration system
- Easy setup
- Emissions readings are averaged, not smoothed, to
eliminate false alarms
- Pre-warning indicator alerts you to potentially
hazardous situations
- Instantaneous alarm or one minute averaged readings
- 4-20 mA output available for use with your PLC
Dust Detect 1000 utilizes triboelectric technology,
whereby the collision and interaction of particles
with the probe rod cause a small electrical charge
transfer to occur. This small electrical charge provides
a signal that is monitored by the electronics. It
is designed to prevent false readings, even if an
accumulation of dust forms on the sensor rod. Emissions
readings are averaged, not smoothed, to eliminate
false alarms. It can be set to make pre-warning indicator
alerts to potentially hazardous situations or be set
to provide an instantaneous alarm or one-minute averaged
readings. BinMaster offers a 4-20 mA output for applications
where Dust Detect 1000 will be used with a PLC.
|
Specifications
|
| Enclosure: |
Die Cast Aluminum, FDA Approved Powder Coat |
| Power Requirement: |
115 VAC, 230 VAC Optional 60/50 Hz |
| Operating Temperature: |
-25° to +160°F (-32° to
+71°C) |
| Stack Temperature: |
+250°F (+107°C) |
| Process Connection: |
1 ¼" NPT |
| Conduit Connection: |
¾" NPT |
| Sensor Red: |
316 Stainless Steel
3, 6, & 12" Standard, 1.5 - 36" Custom Lengths Available |
| Output: |
Two SPDT 5A Relays (warning and alarm)
Optional 4-20 mA Signal |
| Alarm: |
Dual Alarm (alarm is 2x pre-alarm)
Switch Selectable For Instantaneous Or One Minute Average |
| Sensitivity: |
1mg/m (.0005 gr/SCF) |
|
 |