Flow / No Flow Detection for Solids and Powders

The BinMaster flow detect system consists of two components – the FDS1000 Remote Sensor Probe which is mounted in a pneumatic pipeline, gravity chute or feeder – and the FDC1000 Control Console which is mounted in an area accessible for users to read the console during operations. The system promotes continuous and efficient operations by informing users that solid or powder materials are flowing and alerts them if the flow status has changed, power has been lost, or if communication between the Remote Sensor Probe and the Control Console has been interrupted.

The FDS 1000 Remote Sensor Probe is a high quality, industrial grade instrument that senses flow / no-flow conditions using Doppler technology (microwave) to provide highly reliable and sensitive motion detection. It works by transmitting a low energy signal through a Teflon process seal into the material flow stream. A portion of the signal is reflected back to the sensor, with the movement of material causing a frequency shift – called the Doppler shift – which is used by the sensor to detect material flow.

Features
---------------
  • Reliable Doppler technology
  • Can indicate flow/no flow conditions of solids and powders in pipelines, chutes, and feeders
  • Non-intrusive flush mounting senses through non-metallic surfaces
  • Non-contact operation eliminates flow stream interruption and equipment wear
  • Control settings can be made without accessing the remote sensor probe
  • Fail-safe power protection and loop fault monitor
  • "Quick Set" selectable, single turn calibration
  • Explosion proof design

Specifications: Remote Sensor Probe FDS1000
Enclosure: Aluminum, Urethane Powder Coat, NEMA 4X
Power Requirement: Provided By FDC1000 Control Console, Low Voltage
Operating Temperature: -22° to +158°F (-30° to +70°C)
Process Temperature Max: +250°F (+121°C)
If Ambient Air Temperature Is Below +150°F (+65°C)
Process Seal: TFE Teflon
Process Connection: 1 ¼" NPT (flush mount with half coupling)
Conduit Connection: ¾" NPT
Detection Range: Up To 10' Depending On Target
Interconnect Wiring: 5 Conductor Cable to FDC1000 Control Console
Indicators: Green LED - Power
Red LED - Loop Current
Emission: 24.125 GHz, Less Than 1mW/cm2
(OSHA limit is 10mW/cm2)
Approvals: Intrinsically Safe When Connected To FDC1000 Control Unit, Class II, Groups E, F & G, FCC Part 15 Certification

Specifications: Control Console FDC1000
Enclosure: 8" x 6" x 4" Fiberglass, NEMA 4X, 12, 13 Flange Mount
Power Requirement:

115 VAC, 60/50 Hz, 5VA
(230 VAC available)

Operating Temperature: -31° to +158°F (-35° to +70°C)
Output: DPDT Dry Contacts, 5A @ 240 VAC, or 30 VDC
Indicators: Green LED - Power
Red LED - Loop Fault
Yellow LED - Sense Flow
Red LED - Alarm
Interconnect Wiring: 5 Conductor Cable to FDS1000 Sensor, Intrinsically Safe
Alarm Fail-Safe: Switch Selectable FLOW or NO FLOW
Time Delay: FLOW delay, Single Turn, 0.1 - 15 Seconds
NO FLOW delay, Single Turn, 0.1 - 15 Seconds
Sensitivity Adjustment: High/Low Selectable, Single-turn Adjustment
Approvals: Ordinary Locations, Industrial Control Equipment
Intrinsically Safe Output to FDS1000 Sensor